2010 Cadillac Truck SRX AWD V6-3.0L Page 380

2010 Cadillac Truck SRX AWD V6-3.0L Page 380



The air temperature sensors are a 2-wire negative temperature co-efficient thermistor. The vehicle uses the following air temperature sensors:



* Air temperature sensor - left upper



* Air temperature sensor - left lower



* Air temperature sensor - right upper



* Air temperature sensor - right lower



* Air temperature sensor - rear upper (only with CJ4)



* Air temperature sensor - rear lower (only with CJ4)



* A/C evaporator temperature sensor



A signal and low reference circuit enables the sensor to operate. As the air temperature surrounding the sensor increases, the sensor resistance



decreases. The sensor signal voltage decreases as the resistance decreases. The sensor operates within a temperature range between -40 to +85掳C



(-40 to +185掳F). The sensor signal varies between 0-5 V. The HVAC control module converts the signal to a range between 0-255 counts. As the



air temperature increases the count value will decrease. If the HVAC control module detects a malfunctioning sensor, then the control module



software will use a default air temperature value. The default action ensures that the HVAC system can adjust the inside air temperature near the



desired temperature until the condition is corrected.



Conditions for Running the DTC



* Ignition ON.



* The HVAC control module is ON.



Conditions for Setting the DTC



The HVAC control module detects the sensor signal out of range. The signal voltage is less than 0.1 V or greater than 4.9 V for more than 50 ms.



Action Taken When the DTC Sets



The system operates using a default value.



Conditions for Clearing the DTC



The sensor signal is within specified range between 0.1-4.9 V.



Reference Information



Schematic Reference



HVAC Schematics (See: Heating and Air Conditioning/Diagrams/Electrical Diagrams)



Connector End View Reference



Component Connector End Views (See: Diagrams/Connector Views/Connector End Views By Name)



Description and Operation



Automatic HVAC Description and Operation (See: Heating and Air Conditioning/Description and Operation)



Electrical Information Reference



* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit



Testing/Circuit Testing)



* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic



Procedures/Connector Repairs/Connector Repairs)



* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General



Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring



Repairs/Wiring Repairs)



Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information



Circuit/System Verification



Measure actual temperature using a thermometer at each of the duct temperature sensors. Compare this value to the appropriate scan tool Duct



Actual parameter. The measured temperature should be within 5掳C (9掳F) difference of appropriate Duct Actual parameter value.



Circuit/System Testing



1. Ignition OFF, disconnect the harness connector at the appropriate temperature sensor.



2. Test for less than 10 ohm between the temperature sensor ground circuit terminal B and ground.

Comments

Popular posts from this blog

2010 Cadillac Truck SRX AWD V6-3.0L Page 59

2010 Cadillac Truck SRX AWD V6-3.0L Page 968

Disclaimer2020 Lincoln Truck MKT FWD V6-3.7L Technical Service Bulletin # 10-6-3 Date: 100412